Forensic engineering, fire and seismic damage, strenghtening of existing buildings
Inspection, evaluation, strengthening and certification of structural safety for fire-damaged building for KFC Fast Food Restaurant, at 70 Sharah e-Quaid e-Azam, Lahore | KFC
Inspection, evaluation and strengthening of fire-damaged al-Fateh Departmental Store, at Liberty Market | Al-Fatah
Inspection, evaluation, strengthening and certification of structural safety for fire-damaged H. Karim Bukhsh Departmental Store, at Liberty Market | H. K. Enterprises
Inspection, evaluation, strengthening and certification of structural safety for fire-damaged PACE Departmental Store, at Main Boulevard, Gulberg, Lahore | PACE
Preliminary Inspection, Evaluation and Recommendation of Emergency Repairs to Various Structures at the main manufacturing facility of Pakistan Tobacco Company Limited at Jhelum, following Earthquake Event of October 8, 2005 | Pakistan Tobacco Company Limited
Preliminary Inspection, Evaluation and Recommendation of Emergency Repairs to Various Structures at the main manufacturing facility of Pakistan Tobacco Company Limited Akora Khattak and Leaf Godown Facilities in Various Cities, following Earthquake Event of October 8, 2005 | Pakistan Tobacco Company Limited
Preliminary Inspection, Evaluation and Recommendation of Emergency Repairs to the Head Office and Various Residential Buildings Occupied by the Staff of Pakistan Tobacco Company Limited in Islamabad, following Earthquake Event of October 8, 2005 | Pakistan Tobacco Company Limited
Inspection of Head Office Building of the Bank of Punjab at Egerton Road, Lahore,following Earthquake Event of October 8, 2005 | Bank of Punjab
Inspection, Evaluation and Recommendation of Repairs to the Five Storeyed Poultry Farm Complex for Punjab Poultry at Shinkyari, following Earthquake Event of October 8, 2005; Approximate covered area > 100,000 square feet | Punjab Poultry
Inspection, Evaluation and Recommendation of Repairs to the Poultry Farm Complex for Jadeed Poultry at Karmang Bala, following Earthquake Event of October 8, 2005; Approximate covered area > 100,000 square feet | Jadeed Poultry
Seismic Design of hundreds of building and non-building structures, in accordance with UBC, for Zones ranging from 1 to 4.
Design of Equipment Support System for Gravity and Seismic Loads Using Response Spectrum Dynamic Analysis Technique at Chashma Nuclear Plant
Strengthening of Under-construction Building for Leisure Textile Unit-2 Due to Change in Structural System of Roof | Leisure Textile
Strengthening of Existing Polurtry Farm Complex for Bee Bee Jan Farm at Nankana Sahib, for Sadiq Polutry; Covrered Area = 500,000 square feet. | Bee Bee Jan Farm
Industrial ConstructionMills, Silos, Warehouses, Factories
Institutional & commercialOffices, Schools, Hospitals, Hotels
PowerSubstations, Grid stations, Atomic-energy projects
Infrastructure ProjectsBridges, Communication, Roads and surveying
Residential BuildingsApartments, Houses, Mixed occupancy
Retrofit & Forensic Engineering Fire, Seismic & other damage evaluation & monitoring